INSTRUCTIONS FOR USE
GENOTROPIN 5 (JEEN-o-tro-pin 5)
GENOTROPIN PEN 5 is a medical device used to mix and inject doses of reconstituted GENOTROPIN (somatropin) for injection. Use this device only for administration of GENOTROPIN.
Important Note |
Please read these instructions completely before using the GENOTROPIN PEN 5. These instructions need to be followed step by step. Please do not use the GENOTROPIN PEN 5 unless your healthcare provider has trained you. |
Your pen should not be used near electrical or electronic equipment, including mobile phones. If your pen has been damaged, it should not be used and should be disposed of as instructed by your healthcare provider. |
GENOTROPIN PEN 5 is a reusable multi-dose device holding a 2-chamber cartridge of GENOTROPIN, used to mix and inject GENOTROPIN during a 2 year use period.
For your injection you will need:
Parts of the GENOTROPIN PEN 5 (See Figure A)
Storage instructions for your GENOTROPIN PEN 5
Using your GENOTROPIN PEN 5
Wash your hands well with soap and water before using the GENOTROPIN PEN 5.
Step 2. Attach the Needle
| |
| |
| |
Step 3. Insert the 2-Chamber Cartridge of GENOTROPIN | |
| |
| |
Step 4. Prepare your Pen
| |
| |
| |
Step 5. Mix your GENOTROPIN
| |
Step 6. Examine the Solution
| |
| |
Step 7. Release Trapped Air
| |
| |
| |
| |
| |
| |
Step 8. Attach the Needle Guard (Optional) | |
| |
Step 9. Dial Your Prescribed Dose
| |
Step 10. Inject your GENOTROPIN
| |
| |
Step 11. Throw away the Needle and Store your GENOTROPIN PEN 5
| |
Step 12. Your Next Injection | |
| |
| |
| |
Step 13. To Replace the Cartridge
| |
| |
Step 14. Throwing away (disposing of) used needles, cartridges and your GENOTROPIN PEN 5
Put the used needles and cartridges in a FDA-cleared sharps disposal container right away after use. Do not throw away (dispose of) the needles and cartridges in the household trash.
If you do not have a FDA-cleared sharps disposal container, you may use a household container that is:
When your sharps disposal container is almost full, you will need to follow your community guidelines for the right way to dispose of your sharps disposal container. There may be state or local laws about how you should throw away used needles and cartridges. For more information about safe sharps disposal, and for specific information about sharps disposal in the state that you live in, go to the FDA's website at: http://www.fda.gov/safesharpsdisposal.
Important: Always keep the sharps disposal container out of the reach of children.
Dispose of the entire GENOTROPIN PEN 5 as electronic waste per state and local regulations.
Customizing your Pen
Your pen is supplied with 2 colored clip-on panels, so that you can customize the look of your pen. To remove the clip-on panel from the pen, insert the lip of the front cap into the groove under the front end of the panel, and pry the panel off. The new panel simply clicks into place (See Figure AA). |
Caring for your Pen
To clean your pen, wipe the outside surface with a damp cloth. Do not put the pen in water or this may damage your pen. Do not use alcohol or any other cleaning agents to clean the pen, as they may damage the plastic body. To clean the needle guard, wipe it with a damp cloth or alcohol pad.
Questions and Answers | |
---|---|
Question | Answer |
How long is the use period of my pen? | The pen has a use period of 2 years starting from the first use by the patient. |
How can I tell how much GENOTROPIN is left in my pen? | The indicative scale along the side of the cartridge window is a guide. The number that aligns with the front edge of the rubber stopper shows you how many milligrams are left in the cartridge. If your cartridge is nearly empty you can also dial the injection button until it cannot go any further. The dose display will then show the maximum dose that can be delivered. When the cartridge is empty, the injection button will not turn any further. |
If the display does not work, can my pen still be used? | Contact your healthcare provider as soon as possible to get a new pen. |
What happens if I dial the injection button beyond the maximum dose ('2.0' mg)? | Some liquid may appear from the needle tip, and the numbers may disappear from the dose display. This is normal and will not affect your injection. To correct this, turn the injection button in the opposite direction of the arrow until numbers reappear on the dose display. Then dial back to your correct dose. |
Why is it difficult to turn or push the injection button? | The injection button may become difficult to turn or to push. This may occur if the pen gets dirty due to contact with food, liquids or GENOTROPIN, or if the needle becomes clogged. Contact your healthcare provider if the issue does not resolve. |
Display Information:
If you have any questions about your dose or your treatment with GENOTROPIN, call your healthcare provider right away.
Use this device only for the person for whom it was prescribed.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Caution: Federal law restricts this device to sale by or on the order of a physician.
Manufactured by:
Pharmacia & Upjohn Company LLC
A subsidiary of Pfizer Inc.
New York, NY 10001
U.S. License No. 1216
LAB-0225-10.0
Revised August 2024
INSTRUCTIONS FOR USE
GENOTROPIN 12 (JEEN-o-tro-pin 12)
GENOTROPIN PEN 12 is a medical device used to mix and inject doses of reconstituted GENOTROPIN (somatropin) for injection. Use this device only for administration of GENOTROPIN.
Important Note |
Please read these instructions completely before using the GENOTROPIN PEN 12. These instructions need to be followed step by step. Please do not use the GENOTROPIN PEN 12 unless your healthcare provider has trained you. If there is anything you do not understand or cannot do, call the Pfizer Bridge Program toll-free number at 1-800-645-1280. If you have any questions about your dose or your treatment with GENOTROPIN, call your healthcare provider. |
Your pen should not be used near electrical or electronic equipment, including mobile phones. If your pen has been damaged, it should not be used and should be disposed of as instructed by your healthcare provider. |
GENOTROPIN PEN 12 is a reusable multi-dose device holding a 2-chamber cartridge of GENOTROPIN, used to mix and inject GENOTROPIN during a 2 year use period.
For your injection you will need:
Parts of the GENOTROPIN PEN 12 (See Figure A)
Storage instructions for your GENOTROPIN PEN 12
Using your GENOTROPIN PEN 12
Step 1.
Wash your hands well with soap and water before using the GENOTROPIN PEN 12.
Step 2. Attach the Needle
| |
| |
| |
Step 3. Insert the 2-Chamber Cartridge of GENOTROPIN
| |
| |
Step 4. Prepare the Pen
| |
| |
| |
Step 5. Mix your GENOTROPIN
| |
Step 6. Examine the Solution
| |
If you see particles, or if the solution is not clear, do not inject. Remove the cartridge and use a new one. | |
Step 7. Release Trapped Air
| |
| |
| |
| |
| |
| |
Step 8. Attach the Needle Guard (Optional) | |
Be careful not to touch the exposed needle. | |
Step 9. Dial Your Prescribed Dose
| |
Step 10. Inject your GENOTROPIN
| |
| |
Step 11. Throw away the Needle and Store the GENOTROPIN PEN 12
| |
Step 12. Your Next Injection
| |
| |
| |
Step 13. To Replace the Cartridge
| |
| |
Step 14. Throwing away (disposing of) used needles, cartridges and your GENOTROPIN PEN 12
Put the used needles and cartridges in a FDA-cleared sharps disposal container right away after use. Do not throw away (dispose of) the needles and cartridges in the household trash.
If you do not have a FDA-cleared sharps disposal container, you may use a household container that is:
When your sharps disposal container is almost full, you will need to follow your community guidelines for the right way to dispose of your sharps disposal container. There may be state or local laws about how you should throw away used needles and cartridges. For more information about safe sharps disposal, and for specific information about sharps disposal in the state that you live in, go to the FDA's website at: http://www.fda.gov/safesharpsdisposal.
Important: Always keep the sharps disposal container out of the reach of children.
Dispose of the entire GENOTROPIN PEN 12 as electronic waste per state and local regulations.
Customizing your Pen |
Caring for your Pen
To clean your pen, wipe the outside surface with a damp cloth. Do not put the pen in water as this may damage your pen. Do not use alcohol or any other cleaning agents to clean the pen, as they may damage the plastic body. To clean the needle guard, wipe it with a damp cloth or alcohol pad.
Questions and Answers | |
---|---|
Question | Answer |
How long is the use period of my pen? | The pen has a use period of 2 years starting from the first use by the patient. |
How can I tell how much GENOTROPIN is left in my pen? | The indicative scale along the side of the cartridge window is a guide. The number that aligns with the front edge of the rubber stopper shows you how many milligrams are left in the cartridge. If your cartridge is nearly empty you can also dial the injection button until it cannot go any further, the dose display will then show the maximum dose that can be delivered. When the cartridge is empty, the injection button will not turn any further. |
If the display does not work, can my pen still be used? | Contact your healthcare provider as soon as possible to get a new pen. |
What happens if I dial the injection button beyond the maximum dose ('4.0' mg)? | Some liquid may appear from the needle tip, and the numbers may disappear from the dose display. This is normal and will not affect your injection. To correct this, turn the injection button in the opposite direction of the arrow until numbers reappear on the dose display. Then dial back to your correct dose. |
Why is it difficult to turn or push the injection button? | The injection button may become difficult to turn or to push. This may occur if the pen gets dirty due to contact with food, liquids or GENOTROPIN, or if the needle becomes clogged. Contact your healthcare provider if the issue does not resolve. |
Display Information
If you have any questions about your dose or your treatment with GENOTROPIN, call your healthcare provider right away.
Use this device only for the person for whom it was prescribed.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Caution: Federal law restricts this device to sale by or on the order of a physician.
Manufactured by:
Pharmacia & Upjohn Company LLC
A subsidiary of Pfizer Inc.
New York, NY 10001
U.S. License No. 1216
LAB-0224-10.0
Revised August 2024
INSTRUCTIONS FOR USE
GENOTROPIN MINIQUICK (JEEN-o-tro-pin MIN-ee-kwik)
Growth Hormone Delivery Device containing GENOTROPIN (somatropin) for injection
Important Note |
Please read these instructions completely before using GENOTROPIN MINIQUICK. If there is anything you do not understand or cannot do, call the Pfizer Bridge Program toll-free number at 1-800-645-1280. |
GENOTROPIN MINIQUICK is available in 10 dose strengths. Check your GENOTROPIN MINIQUICK to be sure you have the dose your healthcare provider prescribed. |
GENOTROPIN MINIQUICK is a device holding a 2-chamber cartridge of GENOTROPIN, used to mix and inject a single dose of GENOTROPIN.
For each injection you will need:
Parts of the GENOTROPIN MINIQUICK (See Figure A)
Storage instructions for your GENOTROPIN MINIQUICK
Using your GENOTROPIN MINIQUICK
Step 1.
Wash your hands well with soap and water before using the GENOTROPIN MINIQUICK.
Step 2.
Open the plastic bag that contains your GENOTROPIN MINIQUICK by tearing the bag along the dotted lines on the plastic.
Step 3. | |
Step 4. | |
Step 5.
| |
Step 6.
| |
Step 7.
| |
Step 8.
| |
Step 9.
| |
Step 10.
| |
Step 11
|
Step 12. Throwing away (disposing of) your GENOTROPIN MINIQUICK and needles
Put the used GENOTROPIN MINIQUICK and needles in a FDA-cleared sharps disposal container right away after use. Do not throw away (dispose of) the needles and syringes in the household trash.
If you do not have a FDA-cleared sharps disposal container, you may use a household container that is:
When your sharps disposal container is almost full, you will need to follow your community guidelines for the right way to dispose of your sharps disposal container. There may be state or local laws about how you should throw away used needles and syringes. For more information about safe sharps disposal, and for specific information about sharps disposal in the state that you live in, go to the FDA's website at: http://www.fda.gov/safesharpsdisposal.
Important: Always keep the sharps disposal container out of the reach of children.
Questions and Answers | |
---|---|
Question | Answer |
Is it a problem if I see air bubbles in the syringe? | No. There is no need to remove the air bubbles from the GENOTROPIN MINIQUICK. The small amount of air in the syringe does not affect your injection. |
What should I do if I have problems turning the plunger rod (Step 6)? | The problem could be because the needle has been inserted at an angle onto the rubber stopper. |
What should I do if I have problems pushing the plunger when making the injection (Step 10)? | The problem could be because the needle has been inserted at an angle onto the rubber stopper. |
What should I do if the needle is damaged or bent? | Throw away the needle and use a new needle with the GENOTROPIN MINIQUICK. |
If you have any questions about your dose or your treatment with GENOTROPIN, call your healthcare provider right away.
Use this device only for the person for whom it was prescribed.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Manufactured by:
Pharmacia & Upjohn Company LLC
A subsidiary of Pfizer Inc.
New York, NY 10001
U.S. License No. 1216
LAB-0227-9.0
Revised: August 2024
INSTRUCTIONS FOR USE
GENOTROPIN 5 (JEEN-o-tro-pin 5)
GENOTROPIN PEN 5 is a medical device used to mix and inject doses of reconstituted GENOTROPIN (somatropin) for injection. Use this device only for administration of GENOTROPIN.
Important Note |
Please read these instructions completely before using the GENOTROPIN PEN 5. These instructions need to be followed step by step. Please do not use the GENOTROPIN PEN 5 unless your healthcare provider has trained you. |
Your pen should not be used near electrical or electronic equipment, including mobile phones. If your pen has been damaged, it should not be used and should be disposed of as instructed by your healthcare provider. |
GENOTROPIN PEN 5 is a reusable multi-dose device holding a 2-chamber cartridge of GENOTROPIN, used to mix and inject GENOTROPIN during a 2 year use period.
For your injection you will need:
Parts of the GENOTROPIN PEN 5 (See Figure A)
Storage instructions for your GENOTROPIN PEN 5
Using your GENOTROPIN PEN 5
Wash your hands well with soap and water before using the GENOTROPIN PEN 5.
Step 2. Attach the Needle
| |
| |
| |
Step 3. Insert the 2-Chamber Cartridge of GENOTROPIN | |
| |
| |
Step 4. Prepare your Pen
| |
| |
| |
Step 5. Mix your GENOTROPIN
| |
Step 6. Examine the Solution
| |
| |
Step 7. Release Trapped Air
| |
| |
| |
| |
| |
| |
Step 8. Attach the Needle Guard (Optional) | |
| |
Step 9. Dial Your Prescribed Dose
| |
Step 10. Inject your GENOTROPIN
| |
| |
Step 11. Throw away the Needle and Store your GENOTROPIN PEN 5
| |
Step 12. Your Next Injection | |
| |
| |
| |
Step 13. To Replace the Cartridge
| |
| |
Step 14. Throwing away (disposing of) used needles, cartridges and your GENOTROPIN PEN 5
Put the used needles and cartridges in a FDA-cleared sharps disposal container right away after use. Do not throw away (dispose of) the needles and cartridges in the household trash.
If you do not have a FDA-cleared sharps disposal container, you may use a household container that is:
When your sharps disposal container is almost full, you will need to follow your community guidelines for the right way to dispose of your sharps disposal container. There may be state or local laws about how you should throw away used needles and cartridges. For more information about safe sharps disposal, and for specific information about sharps disposal in the state that you live in, go to the FDA's website at: http://www.fda.gov/safesharpsdisposal.
Important: Always keep the sharps disposal container out of the reach of children.
Dispose of the entire GENOTROPIN PEN 5 as electronic waste per state and local regulations.
Customizing your Pen
Your pen is supplied with 2 colored clip-on panels, so that you can customize the look of your pen. To remove the clip-on panel from the pen, insert the lip of the front cap into the groove under the front end of the panel, and pry the panel off. The new panel simply clicks into place (See Figure AA). |
Caring for your Pen
To clean your pen, wipe the outside surface with a damp cloth. Do not put the pen in water or this may damage your pen. Do not use alcohol or any other cleaning agents to clean the pen, as they may damage the plastic body. To clean the needle guard, wipe it with a damp cloth or alcohol pad.
Questions and Answers | |
---|---|
Question | Answer |
How long is the use period of my pen? | The pen has a use period of 2 years starting from the first use by the patient. |
How can I tell how much GENOTROPIN is left in my pen? | The indicative scale along the side of the cartridge window is a guide. The number that aligns with the front edge of the rubber stopper shows you how many milligrams are left in the cartridge. If your cartridge is nearly empty you can also dial the injection button until it cannot go any further. The dose display will then show the maximum dose that can be delivered. When the cartridge is empty, the injection button will not turn any further. |
If the display does not work, can my pen still be used? | Contact your healthcare provider as soon as possible to get a new pen. |
What happens if I dial the injection button beyond the maximum dose ('2.0' mg)? | Some liquid may appear from the needle tip, and the numbers may disappear from the dose display. This is normal and will not affect your injection. To correct this, turn the injection button in the opposite direction of the arrow until numbers reappear on the dose display. Then dial back to your correct dose. |
Why is it difficult to turn or push the injection button? | The injection button may become difficult to turn or to push. This may occur if the pen gets dirty due to contact with food, liquids or GENOTROPIN, or if the needle becomes clogged. Contact your healthcare provider if the issue does not resolve. |
Display Information:
If you have any questions about your dose or your treatment with GENOTROPIN, call your healthcare provider right away.
Use this device only for the person for whom it was prescribed.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Caution: Federal law restricts this device to sale by or on the order of a physician.
Manufactured by:
Pharmacia & Upjohn Company LLC
A subsidiary of Pfizer Inc.
New York, NY 10001
U.S. License No. 1216
LAB-0225-10.0
Revised August 2024
INSTRUCTIONS FOR USE
GENOTROPIN 12 (JEEN-o-tro-pin 12)
GENOTROPIN PEN 12 is a medical device used to mix and inject doses of reconstituted GENOTROPIN (somatropin) for injection. Use this device only for administration of GENOTROPIN.
Important Note |
Please read these instructions completely before using the GENOTROPIN PEN 12. These instructions need to be followed step by step. Please do not use the GENOTROPIN PEN 12 unless your healthcare provider has trained you. If there is anything you do not understand or cannot do, call the Pfizer Bridge Program toll-free number at 1-800-645-1280. If you have any questions about your dose or your treatment with GENOTROPIN, call your healthcare provider. |
Your pen should not be used near electrical or electronic equipment, including mobile phones. If your pen has been damaged, it should not be used and should be disposed of as instructed by your healthcare provider. |
GENOTROPIN PEN 12 is a reusable multi-dose device holding a 2-chamber cartridge of GENOTROPIN, used to mix and inject GENOTROPIN during a 2 year use period.
For your injection you will need:
Parts of the GENOTROPIN PEN 12 (See Figure A)
Storage instructions for your GENOTROPIN PEN 12
Using your GENOTROPIN PEN 12
Step 1.
Wash your hands well with soap and water before using the GENOTROPIN PEN 12.
Step 2. Attach the Needle
| |
| |
| |
Step 3. Insert the 2-Chamber Cartridge of GENOTROPIN
| |
| |
Step 4. Prepare the Pen
| |
| |
| |
Step 5. Mix your GENOTROPIN
| |
Step 6. Examine the Solution
| |
If you see particles, or if the solution is not clear, do not inject. Remove the cartridge and use a new one. | |
Step 7. Release Trapped Air
| |
| |
| |
| |
| |
| |
Step 8. Attach the Needle Guard (Optional) | |
Be careful not to touch the exposed needle. | |
Step 9. Dial Your Prescribed Dose
| |
Step 10. Inject your GENOTROPIN
| |
| |
Step 11. Throw away the Needle and Store the GENOTROPIN PEN 12
| |
Step 12. Your Next Injection
| |
| |
| |
Step 13. To Replace the Cartridge
| |
| |
Step 14. Throwing away (disposing of) used needles, cartridges and your GENOTROPIN PEN 12
Put the used needles and cartridges in a FDA-cleared sharps disposal container right away after use. Do not throw away (dispose of) the needles and cartridges in the household trash.
If you do not have a FDA-cleared sharps disposal container, you may use a household container that is:
When your sharps disposal container is almost full, you will need to follow your community guidelines for the right way to dispose of your sharps disposal container. There may be state or local laws about how you should throw away used needles and cartridges. For more information about safe sharps disposal, and for specific information about sharps disposal in the state that you live in, go to the FDA's website at: http://www.fda.gov/safesharpsdisposal.
Important: Always keep the sharps disposal container out of the reach of children.
Dispose of the entire GENOTROPIN PEN 12 as electronic waste per state and local regulations.
Customizing your Pen |
Caring for your Pen
To clean your pen, wipe the outside surface with a damp cloth. Do not put the pen in water as this may damage your pen. Do not use alcohol or any other cleaning agents to clean the pen, as they may damage the plastic body. To clean the needle guard, wipe it with a damp cloth or alcohol pad.
Questions and Answers | |
---|---|
Question | Answer |
How long is the use period of my pen? | The pen has a use period of 2 years starting from the first use by the patient. |
How can I tell how much GENOTROPIN is left in my pen? | The indicative scale along the side of the cartridge window is a guide. The number that aligns with the front edge of the rubber stopper shows you how many milligrams are left in the cartridge. If your cartridge is nearly empty you can also dial the injection button until it cannot go any further, the dose display will then show the maximum dose that can be delivered. When the cartridge is empty, the injection button will not turn any further. |
If the display does not work, can my pen still be used? | Contact your healthcare provider as soon as possible to get a new pen. |
What happens if I dial the injection button beyond the maximum dose ('4.0' mg)? | Some liquid may appear from the needle tip, and the numbers may disappear from the dose display. This is normal and will not affect your injection. To correct this, turn the injection button in the opposite direction of the arrow until numbers reappear on the dose display. Then dial back to your correct dose. |
Why is it difficult to turn or push the injection button? | The injection button may become difficult to turn or to push. This may occur if the pen gets dirty due to contact with food, liquids or GENOTROPIN, or if the needle becomes clogged. Contact your healthcare provider if the issue does not resolve. |
Display Information
If you have any questions about your dose or your treatment with GENOTROPIN, call your healthcare provider right away.
Use this device only for the person for whom it was prescribed.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Caution: Federal law restricts this device to sale by or on the order of a physician.
Manufactured by:
Pharmacia & Upjohn Company LLC
A subsidiary of Pfizer Inc.
New York, NY 10001
U.S. License No. 1216
LAB-0224-10.0
Revised August 2024
INSTRUCTIONS FOR USE
GENOTROPIN MINIQUICK (JEEN-o-tro-pin MIN-ee-kwik)
Growth Hormone Delivery Device containing GENOTROPIN (somatropin) for injection
Important Note |
Please read these instructions completely before using GENOTROPIN MINIQUICK. If there is anything you do not understand or cannot do, call the Pfizer Bridge Program toll-free number at 1-800-645-1280. |
GENOTROPIN MINIQUICK is available in 10 dose strengths. Check your GENOTROPIN MINIQUICK to be sure you have the dose your healthcare provider prescribed. |
GENOTROPIN MINIQUICK is a device holding a 2-chamber cartridge of GENOTROPIN, used to mix and inject a single dose of GENOTROPIN.
For each injection you will need:
Parts of the GENOTROPIN MINIQUICK (See Figure A)
Storage instructions for your GENOTROPIN MINIQUICK
Using your GENOTROPIN MINIQUICK
Step 1.
Wash your hands well with soap and water before using the GENOTROPIN MINIQUICK.
Step 2.
Open the plastic bag that contains your GENOTROPIN MINIQUICK by tearing the bag along the dotted lines on the plastic.
Step 3. | |
Step 4. | |
Step 5.
| |
Step 6.
| |
Step 7.
| |
Step 8.
| |
Step 9.
| |
Step 10.
| |
Step 11
|
Step 12. Throwing away (disposing of) your GENOTROPIN MINIQUICK and needles
Put the used GENOTROPIN MINIQUICK and needles in a FDA-cleared sharps disposal container right away after use. Do not throw away (dispose of) the needles and syringes in the household trash.
If you do not have a FDA-cleared sharps disposal container, you may use a household container that is:
When your sharps disposal container is almost full, you will need to follow your community guidelines for the right way to dispose of your sharps disposal container. There may be state or local laws about how you should throw away used needles and syringes. For more information about safe sharps disposal, and for specific information about sharps disposal in the state that you live in, go to the FDA's website at: http://www.fda.gov/safesharpsdisposal.
Important: Always keep the sharps disposal container out of the reach of children.
Questions and Answers | |
---|---|
Question | Answer |
Is it a problem if I see air bubbles in the syringe? | No. There is no need to remove the air bubbles from the GENOTROPIN MINIQUICK. The small amount of air in the syringe does not affect your injection. |
What should I do if I have problems turning the plunger rod (Step 6)? | The problem could be because the needle has been inserted at an angle onto the rubber stopper. |
What should I do if I have problems pushing the plunger when making the injection (Step 10)? | The problem could be because the needle has been inserted at an angle onto the rubber stopper. |
What should I do if the needle is damaged or bent? | Throw away the needle and use a new needle with the GENOTROPIN MINIQUICK. |
If you have any questions about your dose or your treatment with GENOTROPIN, call your healthcare provider right away.
Use this device only for the person for whom it was prescribed.
This Instructions for Use has been approved by the U.S. Food and Drug Administration.
Manufactured by:
Pharmacia & Upjohn Company LLC
A subsidiary of Pfizer Inc.
New York, NY 10001
U.S. License No. 1216
LAB-0227-9.0
Revised: August 2024
{{section_body_html_patient}}
Chat online with Pfizer Medical Information regarding your inquiry on a Pfizer medicine.
*Speak with a Pfizer Medical Information Professional regarding your medical inquiry. Available 9AM-5PM ET Monday to Friday; excluding holidays.
Submit a medical question for Pfizer prescription products.
Pfizer Safety
To report an adverse event related to the Pfizer-BioNTech COVID-19 Vaccine, and you are not part of a clinical trial* for this product, click the link below to submit your information:
Pfizer Safety Reporting Site*If you are involved in a clinical trial for this product, adverse events should be reported to your coordinating study site.
If you cannot use the above website, or would like to report an adverse event related to a different Pfizer product, please call Pfizer Safety at (800) 438-1985.
FDA Medwatch
You may also contact the U.S. Food and Drug Administration (FDA) directly to report adverse events or product quality concerns either online at www.fda.gov/medwatch or call (800) 822-7967.